Filter
Cell analyzer CyTUM-MIH
CytoFlex

3 laser: 405nm, 488nm, 638nm

  • Cuvette based Cell Analyzer 200 µm size
  • Daily user based QC validation
  • Up to 30.000 eps (Events per Second) – recommended 10.000 eps
  • Data size max.: 1*107 events
  • Freely adjustable flow rates 10 – 240 µl/min
  • Multiple format for sampling 5ml, 1.5ml, Eppendorf; default: plate loader 96-well
  • Automatic sample agitation
  • APD (Avalanche Photodiode) based detection system with high resolution lin/log scaling up to 7 log decades
  • Sensitivity FITC < 30 molecules, PE < 10 molecules MESF
  • Small particle resolution down to 200 nm size

Filter layout

Image
CytoFlex
CytoFlex S

4 laser: 405nm, 488nm, 561nm, 638nm

  • Cuvette based Cell Analyzer 200 µm size
  • Daily user based QC validation
  • Up to 30.000 eps (Events per Second) – recommended 10.000 eps
  • Data size max.: 1*107 events
  • Freely adjustable flow rates 10 – 240 µl/min
  • Multiple format for sampling 5ml, 1.5ml, Eppendorf; default: plate loader 96-well
  • Automatic sample agitation
  • APD (Avalanche Photodiode) based detection system with high resolution lin/log scaling up to 7 log decades
  • Sensitivity FITC < 30 molecules, PE < 10 molecules MESF
  • Small particle resolution down to 200 nm size

Filterlayout

Image
CytoFlex S
CytoFlex LX

6 laser: 375nm, 405nm, 488nm, 561nm, 638nm, 808nm

  • Cuvette based Cell Analyzer 200 µm size
  • Daily user based QC validation
  • Up to 30.000 eps (Events per Second) – recommended 10.000 eps
  • Data size max.: 1*107 events
  • Freely adjustable flow rates 10 – 240 µl/min
  • Multiple format for sampling 5ml, 1.5ml, Eppendorf; default: plate loader 96-well
  • Automatic sample agitation
  • APD (Avalanche Photodiode) based detection system with high resolution lin/log scaling up to 7 log decades
  • Sensitivity FITC < 30 molecules, PE < 10 molecules MESF
  • Small particle resolution down to 200 nm size

Filterlayout LX 2.OG

Filterlayout LX 3.OG

Image
CytoFlex LX
Cytek Aurora

5 Laser: 355nm, 405nm, 488nm, 561nm, 640nm 

  • Cuvette based Cell Analyzer 200 µm size
  • Daily user based QC validation
  • Up to 35.000 eps (Events per Second) – recommended 10.000 eps
  • Freely adjustable flow rates 15 – 100 µl/min
  • Multiple format for sampling 5ml, 1.5ml; plate loader 96, 48-well freely adjustable
  • APD (Avalanche Photodiode) based spectral detection system with high resolution in 67 channels, scaling up to 6.5 log decades
  • Small particle resolution down to 200 nm size

Spectrum viewer

Image
Cytek Aurora